Alarm Terminal Setup - Panasonic WJ-FS616C Operating Instructions Manual

Video multiplexer
Hide thumbs Also See for WJ-FS616C:
Table of Contents

Advertisement

9. Cable Compensation/VD2/ Data
This item lets you select the optimum setting for the
cable-loss compensator and whether to supply the
VD2 (sync) signal or control data to the camera.
Note: These settings will work only for the input
channels that have the multiplex feature with
the Data Mutiplex Board WV-BP6164 installed.
The boards are installed for input channels 1
through 4 at the factory. You can install boards
for other channels. For installations, see page
10.
1. Move the cursor to CABLE COMP/VD2/DATA
SETUP on the SYSTEM MENU, then press the
SET
button.
The
SETUP table shown below appears on the mon-
itor screen.
CABLE COMP/VD2/DATA SETUP 1 OF 2
CAM
CABLE
1CH
S
2CH
S
3CH
S
4CH
S
5CH
S
6CH
S
7CH
S
8CH
S
CABLE COMP/VD2/DATA SETUP 2 OF 2
CAM
CABLE
9CH
S
10CH
S
11CH
S
12CH
S
13CH
S
14CH
S
15CH
S
16CH
S
Press the FUNCTION button to display the next
page, then press this button again to return to
the previous page.
2. Move the cursor to the channel you want to edit
by pressing the Direction Arrow Buttons.
3. Select one of the parameters shown below in
the CABLE area by pressing the Increment (+)
or Decrement ( ) button.
S: Up to 400 m (1 300 ft)
M: 400 m (1 300 ft) to 700 m (2 300 ft)
L: 700 m (2 300 ft) to 900 m (3 000 ft)
When using the RG-59/U, BELDEN 9259 or
equivalent cable.
Note: Set CABLE to S if no camera is connect-
ed to the channel.
4. Select ON or OFF in the VD2 area by pressing
the Increment (+) or Decrement ( ) button.
Note: Select ON for a camera with VD2 capabil-
ity, otherwise select OFF.
CABLE COMP/VD2/DATA
VD2
DATA
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
VD2
DATA
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
5. Select one of the parameters shown below in
the DATA area by pressing the Increment (+) or
Decrement ( ) button.
ON: Communicates with the camera site by
multiplexed data.
1-16: Communicate with the camera site by RS-
485.
This number indicates the unit address of
the selected camera.
OFF: Disables communication with the camera
site.
6. Repeat the above procedures to edit other
channels.
7. Press the SETUP/ESC button to execute the set-
ting and return to the previous SYSTEM SETUP
menu.
Note: Installation of the WV-PB6164 Data Multi-
plex Boards is required for controlling more
than 4 cameras.

10. Alarm Terminal Setup

This item lets you edit the alarm input number cor-
responding to each channel.
1. Move the cursor to ALM TERMINAL SETUP on
the SYSTEM SETUP menu, then press the SET
button. The ALARM TERMINAL SETUP table
shown below appears on the monitor screen.
ALARM TERMINAL SETUP
NO.
CAM
1
1CH
2
2CH
3
3CH
4
4CH
5
5CH
6
6CH
7
7CH
8
8CH
2. Move the cursor to the number you want to edit
by pressing the Derection Arrow Buttons.
3. Select the channel to be assigned in the CAM
area
by
Decrement (–) button.
Note: Channel numbers can also be input
directly with the camera Number Buttons.
4. Select the preset position number to be
assigned in the PRE area by pressing the
Increment (+) or Decrement (–) button.
5. Repeat the above procedures to assign other
terminal numbers.
6. Press the SETUP/ESC button to execute the set-
ting and return to the previous SYSTEM SETUP
menu.
Note: The same channel can be assigned to
multiple alarm terminals.
In this case, different preset positions can
be assigned, but when alarm occurs at
these positions, the camera moves to the
preset position where the most recent alarm
occurred.
-34-
PRE
NO.
CAM
PRE
-
9
9CH
-
-
10
10CH
-
-
11
11CH
-
-
12
12CH
-
-
13
13CH
-
-
14
14CH
-
-
15
15CH
-
-
16
16CH
-
pressing
the
Increment
(+)
or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-fs616

Table of Contents