Alarm Setup Menu - Panasonic WJ-FS316 Operating Instructions Manual

Video multiplexer
Table of Contents

Advertisement

Alarm Setup Menu

WJ-FS316 SETUP
ALARM SETUP
MONITOR OUTPUT SETUP
REC OUTPUT SETUP
SEQUENCE SETUP
SYSTEM SETUP
Move the cursor to ALARM SETUP on the SETUP menu,
then press the SET button. The ALARM SETUP menu
appears on the monitor screen as shown below.
DYNAMIC REC
ALM REC MODE
AUTO RESET
ALM DISPLAY
ALM OUTPUT
ALM BUZZER
ALM INPUT
VIDEO LOSS
MLT OUT MODE
SPT OUT MODE
1. DYNAMIC REC
This item lets you select the camera channel(s) whose pic-
ture is to be recorded on the VCR when an alarm signal is
received. There are priority options for recording of chan-
nel(s) ranging from equal priority of all channels to exclu-
sive recording of a specified channel.
1. Move the cursor to the DYNAMIC REC parameter.
2. Select OFF, ALM - PRI, ALM-ONLY or GROUP by
pressing the + or – button.
The initial factory setting is OFF.
OFF: The video signals are recorded from channels
number 1 to 9 (WJ-FS309/FS409) or 1 to 16 (WJ-FS
316/FS416) regardless of any channels receiving
the alarm signal.
ALM - PRI: The video signal of the channel that
received the alarm signal is recorded with more
fields than normal.
ALM-ONLY: The recording output is monopolized by
the picture of the channel that received the alarm,
while the pictures on other channels are omitted.
Note: ALM-ONLY is not applicable, when a WJ-DR200
AV Disc Recorder is connected to the unit.
GROUP: Up to 4 channels are merged into a group.
When an alarm is received, the video signals of this
channel group are recorded with more fields than
normal.
If the DYNAMIC REC parameter is on GROUP, proceed
as follows:
11
ALARM SETUP
OFF
004
OFF
ON
2S
2S
N.O.
ON
SPOT
SPOT
<WJ-FS309/FS409>
GROUP SETUP
CH
ALM 1
1
ALM 2
2
ALM 3
3
ALM 4
4
ALM 5
5
ALM 6
6
ALM 7
7
ALM 8
8
ALM 9
9
<WJ-FS316/FS416>
GROUP SETUP
CH
ALM 1
1
ALM 2
2
ALM 3
3
ALM 4
4
ALM 5
5
ALM 6
6
ALM 7
7
ALM 8
8
1. Move the cursor on GROUP in the DYNAMIC REC
line and press the SET button to open the GROUP
SETUP menu shown above.
2. Move the cursor to the desired position by pressing
the C, D, A, B buttons.
Note: To turn over the page for WJ-FS316/FS416,
keep the cursor moving up or down.
3. Select the camera number by pressing the
Increment (+) or Decrement (–) button.
4. Repeat steps 2 and 3 until all groupings are
entered.
Note: Assigning one camera channel to plural
alarm inputs is acceptable.
2. ALM REC MODE
This item lets you select the time interval (field rate) for
switching the camera channel for the REC OUT signal. This
setting takes effect only when an alarm is activated.
1. Move the cursor to the ALM REC MODE parameter.
2. Select a field rate or EXT by pressing the + or – button.
The initial factory setting is 004.
004 - 128: REC OUT signal is switched from one cam-
era channel to another at the field rate specified
here. The appropriate field rate may vary depend-
ing on the VCR model. Consult the VCR specifica-
tions on the field rate.
EXT: Switching of the REC OUT signal is controlled by
the camera switching signal supplied by the con-
nected VCR.
CH
CH
CH
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
2/2
1/2
CH
CH
CH
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-fs309Wj-fs409Wj-fs416

Table of Contents