Preset Position
1. Move the cursor to the step number you want to
edit in the PRE area by pressing the Derection
Arrow Buttons.
2. Select the desired preset position number in the
PRE area by pressing the Increment (+) or
Decrement (–) button.
Note: A preset position assigned to a step that has
been assigned to a playback channel is invalid.
3. Repeat the above procedures to assign other
steps.
Dwell Time
• Uniform Dwell Time
1. Move the cursor to the DWELL TIME parameter.
2. Select the desired dwell time by pressing the
LEFT or RIGHT button.
Dwell Time can be selected between 0SEC and
30SEC.
Note: If 0SEC is selected for dwell time, the
spot sequence is not activated.
• Individual Dwell Time
1. Move the cursor to the step number you want to
edit in the TIME area by pressing the Directon
Arrow buttons.
2. Select the desired dwell time by pressing the
Increment (+) or Decrement ( ) button.
Steps for which a different dwell time has been
selected are marked " " in the DWELL TIME
area. Previous settings made in the DWELL
TIME area become invalid.
Programming Steps 17 to 32
1. Press the FUNCTION button to display the next
page. The table shown below appears on the moni-
tor screen.
SEQ1(SPOT-SEQUENCE)SETUP 2 OF 2
STEP CAM PRE TIME
17
-
-
2SEC
18
-
-
2SEC
19
-
-
2SEC
20
-
-
2SEC
21
-
-
2SEC
22
-
-
2SEC
23
-
-
2SEC
24
-
-
2SEC
2. Program the sequence pattern for steps 17 to
32 as described for the previous page.
3. Press the FUNCTION button to display the pre-
vious page.
4. After finishing the setting, press the SET
UP/ESC button to execute the setting and return
to the previous SYSTEM SETUP menu.
STEP CAM PRE TIME
25
-
-
2SEC
26
-
-
2SEC
27
-
-
2SEC
28
-
-
2SEC
29
-
-
2SEC
30
-
-
2SEC
31
-
-
2SEC
32
-
-
2SEC
Multi Sequence (SEQ2, SEQ3)
This item lets you program or edit a Multi
Sequence. Up to 5 steps can be assigned in the
table shown below.
You can also enable the Auto Skip function to skip
any steps where no video signal is present.
The duration of each step is determined by the
Dwell Time setting.
According to the initial factory setting, SEQ2 is dis-
played on four screen segments (quad) and SEQ3
on nine segments.
1. Move the cursor to the SEQUENCE SETUP
parameter on the SYSTEM SETUP menu.
2. Select SEQ2 or SEQ3 by pressing the LEFT or
RIGHT button, then press the SET button. The
setup menu shown below appears on the moni-
tor screen.
SEQ2(MULTI-SEQUENCE)SETUP 1 OF 5
AUTO SKIP
STEP 1
DWELL TIME 3SEC
AREA
1
2
3
4
5
6
7
8
SEQ3(MULTI-SEQUENCE)SETUP 1 OF 5
AUTO SKIP
STEP 1
DWELL TIME 5SEC
AREA
1
2
3
4
5
6
7
8
Auto Skip
1. Move the cursor to the AUTO SKIP parameter.
2. Select ON or OFF by pressing the LEFT or RIGHT
button. The initial factory setting is ON.
ON: Enables the auto skip function.
OFF: Disables the auto skip function.
Note: The AUTO SKIP function is not available
when playing back pictures.
Camera / Playback
This item lets you select the camera or playback picture
to be displayed at each step.
1. Move the cursor to the STEP parameter.
2. Select CAM or PLAY by pressing the LEFT or
RIGHT button.
CAM: Enables display of camera picture.
PLAY: Enables display of playback picture.
-32-
OFF
CAM
CAM PRE
AREA
CAM PRE
1CH
-
9
-
-
2CH
-
10
-
-
3CH
-
11
-
-
4CH
-
12
-
-
-
-
13
-
-
-
-
14
-
-
-
-
15
-
-
-
-
16
-
-
OFF
CAM
CAM PRE
AREA
CAM PRE
1CH
-
9
-
-
2CH
-
10
-
-
3CH
-
11
-
-
4CH
-
12
-
-
5CH
-
13
-
-
6CH
-
14
-
-
7CH
-
15
-
-
8CH
-
16
-
-