Alarm Buzzer Duration; Alarm Display On The Monitors; Alarm Output Duration - Panasonic WJ-FS616C Operating Instructions Manual

Video multiplexer
Hide thumbs Also See for WJ-FS616C:
Table of Contents

Advertisement

4. Camera Switching Pulse Loss
Alarm
This item lets you enable or disable alarm display
on the monitor screen when the camera switching
pulse is lost.
1. Move the cursor to the SW-LOSS ALM parame-
ter.
2. Select ON or OFF by pressing the LEFT or
RIGHT button. The initial factory setting is OFF.
ON: Enables alarm display on the monitor
screen.
OFF: Disables alarm display on the monitor
screen.

5. Alarm Display on the Monitors

This item lets you enable or disable alarm display
on the Spot and Multiscreen Monitors.
1. Move the cursor to the ALM DISPLAY parame-
ter.
2. Select ON or OFF by pressing the LEFT or
RIGHT button. The initial factory setting is ON.
ON: Enables alarm display on the Monitors.
OFF: Disables alarm display on the Monitors.

6. Alarm Output Duration

This item lets you select the duration of alarm signal
output.
The alarm is automatically reset after the pro-
grammed duration has passed.
1. Move the cursor to the ALM OUTPUT DUR
parameter.
2. Select the desired duration by pressing the
LEFT or RIGHT button. The initial factory setting
is 2 SEC.
1SEC - 5MIN: Selects an alarm duration
between 1 second and 5 minutes.
EXT: Alarm continues until the ALARM RESET
button is pressed or the external alarm reset
signal is received.

7. Alarm Buzzer Duration

This item lets you select the ringing duration of the
alarm buzzer when alarm is activated.
1. Move the cursor to the ALM BUZZER DUR
parameter.
2. Select the desired duration by pressing the
LEFT or RIGHT button. The initial factory setting
is 2 SEC.
OFF: Disables the alarm buzzer output.
1SEC - 5 MIN: Selects a buzzer duration
between 1 second and 5 minutes.
EXT: The alarm buzzer continues to beep until
the ALARM RESET button is pressed, or an
external alarm recover signal is received.
8. Alarm Mode on Multiscreen
Monitor
This item lets you select the mode for displaying an
alarm on the Multiscreen Monitor.
1. Move the cursor to the ALM MODE-MLT para-
meter.
2. Select the desired mode by pressing the LEFT
or RIGHT button. The initial factory setting is
ALM-IND mode.
ALM-LINK: Switches screen to the camera pic-
ture of the corresponding channel with an
alarm title super- imposed.
ALM-IND: Retains the camera picture currently
selected. An alarm title appears overlapped
on the camera picture. If no camera is cur-
rently selected the alarm title does not
appear.
3. When ALM-LINK is selected on this menu, the
cursor can be moved to DWELL TIME.
• Dwell Time for Alarm Sequence
If more than one alarm is activated when ALM-LINK
is selected, the respective camera pictures are dis-
played on the Multiscreen Monitor in quad mode.
From the fifth alarm on, the pictures are displayed
sequentially in quad mode.
This item lets you set the dwell time for the alarm
sequence.
1. Move the cursor to DWELL TIME parameter.
2. Select the desired dwell time by pressing the
LEFT or RIGHT button. The initial factory setting
is 2 seconds.
1SEC - 30SEC: Selects a dwell time between 1
second and 30 seconds.