3-20.5 Statistics - ZyXEL Communications XGS3600 Series Manual

Gbe l2 switch with 10g gbe uplink
Table of Contents

Advertisement

3-20.5 Statistics

This chapter introduces how to provide detailed OAM traffic statistics for a specific switch port.
Use the port select box to select which switch port details to display. The displayed counters
represent the total number of OAM frames received and transmitted for the selected port.
Discontinuities of these counters can occur at re-initialization of the management system.
Web Interface
To display the Statistics in the web interface:
1. Click Configuration, 802.3ah OAM then Statistics.
2. Scroll to select which port you want to monitor the Statistics.
3. Evoke auto-refresh to update the detailed Link Events data.
4. Click the Refresh to update the Link OAM Port statistics.
.
Figure 3-20.5: The detailed Link OAM Port Statistics
Parameter description:
Port :
You can scroll to select which port you want to monitor detailed Link OAM events. It shows
the switch port number.
Rx and Tx OAM Information PDU's :
The number of received and transmitted OAM Information PDU's.Discontinuities of this
counter can occur at re-initialization of the management system.
Rx and Tx Unique Error Event Notification :
A count of the number of unique Event OAMPDUs received and transmitted on this
interface. Event Notifications may be sent in duplicate to increase the probability of
successfully being received, given the possibility that a frame may be lost in transit.
Duplicate Event Notification transmissions are counted by Duplicate Event Notification
counters for Tx and Rx respectively. A unique Event Notification OAMPDU is indicated as
an Event Notification OAMPDU with a Sequence Number field that is distinct from the
previously transmitted Event Notification OAMPDU Sequence Number.
Rx and Tx Duplicate Error Event Notification :
A count of the number of duplicate Event OAMPDUs received and transmitted on this
interface. Event Notification OAMPDUs may be sent in duplicate to increase the probability
of successfully being received, given the possibility that a frame may be lost in transit. A
duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU with
a Sequence Number field that is identical to the previously transmitted Event Notification
OAMPDU Sequence Number.
Rx and Tx Loopback Control :
A count of the number of Loopback Control OAMPDUs received and transmitted on this
interface.
XGS3600 Series User's Guide
248

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xgs3600-26fXgs3600-28Xgs3600-28f

Table of Contents