3-16 Loop Protection

The loop detection is used to detect the presence of traffic. When switch receives packet's
(looping detection frame) MAC address the same as oneself from port, show Loop Protection
happens. The port will be locked when it received the looping detection frames. If you want to
resume the locked port, please find out the looping path and take off the looping path, then
select the resume the locked port and click on "Resume" to turn on the locked ports.

3-16.1 Configuration

This page allows the user to inspect the current Loop Protection configurations, and possibly
change them as well.
Web Interface
To configure the Loop protection parameters in the web interface:
1. Click Configuration, Loop Protection, Configuration.
2. Scroll all parameters and evoke the Enable
3. Click the Apply to save the setting
4. If you want to cancel the setting then you need to click the Reset button.
It will revert to previously saved values
Figure 3-16.1: The Configuration
XGS3600 Series User's Guide