Setting Contents And Code No. For Indoor Units - Daikin VRV-WIII RWEYQ72PTJU Service Manual

Water cooled heat pump / heat recovery
Hide thumbs Also See for VRV-WIII RWEYQ72PTJU:
Table of Contents

Advertisement

Field Setting from Remote Controller
2.4

Setting Contents and Code No. for Indoor Units

Mode
First
No.
Code
(2)
No.
Filter contamination heavy/
light (Setting for display time
to clean air filter)
0
(Sets display time to clean air
filter to half when there is
heavy filter contamination.)
0 (6) Filter dirt
1
Long life filter type
1 (6) Filter cleaning sign time (Light/Heavy)
10(20)
2
Selection of thermistor
2 (6) Remote sensor and remote controller thermistor
Display time to clean air filter calculation (Set
3
when filter sign is not to be displayed.)
7
4 step thermostat processing
3 (6) Electric heater setting
11
(21)
4 (6) Electric heater step setting
Optional accessories output selection (field
0
selection of output for adaptor for wiring)
ON/OFF input from condensing (Set when ON/
1
OFF is to be controlled from outside.)
Thermostat differential changeover
2
(Set when remote sensor is to be used.)
12(22)
3
Airflow setting when heating thermostat is OFF
Automatic mode differential (automatic
4
temperature differential setting for VRV system
heat recovery series cool/heat)
5
Power failure automatic reset
6
Airflow setting when cooling thermostat is OFF
0
Setting of normal airflow
Selection of airflow direction
1
(Set when a blocking pad kit has been installed.)
13(23)
3
Operation of downward flow flap: Yes/No
4
Field setting airflow position setting
5
Setting of static pressure selection
4 (6) Setting of humidifier / air purifier fan tap
14
(24)
5 (6) Humidifier residual operation time
1
Thermostat OFF excess humidity
Direct duct connection
2
(when the indoor unit and heat reclaim ventilator
unit are connected by duct directly.) (5)
15(25)
3
Drain pump humidifier interlock selection
Field setting selection for individual ventilation
5
setting by remote controller
92
Setting Contents
Ultra long life
filter
Long life filter
Standard
filter
Second Code No.
01
Approx.
10,000
hrs.
Approx.
Light
Heavy
2,500
hrs.
Approx.
200 hrs.
Light
Heavy
Long life filter
Ultra long life filter
2,500/1,250
10,000/5,000
Remote controller +
Only body
Body thermostat
thermostat
Both
Remote thermistor
Display
No display
Symbol (8)
01
02
Ttson
-7.2°F
-6.3°F
Ttsoff
-3.6°F
-2.7°F
Heat Pump lockout
mode
With heater
Indoor unit turned
ON by thermostat
Forced OFF
ON/OFF control
1.8°F
0.9°F (7)
LL
Set fan speed
01:0
02:1.8
03:3.6
Not equipped
Equipped
LL
Set fan speed
N
F (4 directions)
T (3 directions)
Equipped
Not equipped
Draft prevention
Standard
Standard
High static pressure
Remote controller
H tap
setting
30 sec.
60 sec.
Not equipped
Equipped
Not equipped
Equipped
Not equipped
Equipped
Not equipped
Equipped
: Factory setting
02
03
Approx.
5,000
hrs.
Approx.
1,250
hrs.
Approx.
100 hrs.
Only remote
controller
thermostat
Remote
controller
thermistor
03
04
05
-5.4°F
-4.5°F
-3.6°F
-1.8°F
-0.9°F
0°F
Auxiliary
electric heater
+ Heat Pump
lockout mode
Without heater
Operation
output
External
protection
device input
04:5.4
05:7.2 06:9.0
H
S
W
(2 directions)
Ceiling Soiling
prevention
120 sec.
SiUS30-1301
04
06
-2.7°F
0.9°F
Error output
07:10.8
08:12.6
Field Setting