RRP 2-15Trays 3, 4, and 5 No Paper Sensors
(PL 12.3~PL 12.4)
No Paper Sensor
Fig 2-20 Trays 3, 4, and 5 No Paper Sensors
Use this procedure for removing and replacing the No Paper Sensors for Trays 3, 4, and 5.
Removal
1.
Remove the Paper Tray associated with the No Paper Sensor you are going to
remove.
2.
Squeeze the Sensor latches and remove the No Paper Sensor from the frame.
3.
Disconnect the P/J from the Sensor.
Replacement
1.
Reconnect the P/J to the Sensor.
2.
Push the No Paper Actuator up and out of the way.
3.
Position the Sensor with the arms of the Sensor facing the Actuator.
4.
Reinstall the No Paper Sensor into the slot in the frame by first inserting the
front latch of the Sensor through the front opening in the frame.
5.
Press in on the rear latch and inserting it into the rear opening.
6.
Release the rear latch and the Sensor snaps into place.
7.
Release the Actuator and make sure it moves freely between the arms of the
Sensor.
8.
Reconnect the P/J to the Sensor.
9.
Reinstall the Paper Tray.
Volume 2 / High Capacity Feeder - RRPs