8.7

HYDRAULIC SYSTEM FLUSHING _____________________________________

When changing from mineral to Greenscare™ Bio-degradable oil.
Terresolve™ EnviroLogic ® BioFlush is a carefully designed fluid which helps to flush and remove petroleum oil
from hydraulic systems. This is done when converting hydraulic systems to the use of biodegradable fluids.
EnviroLogic ® BioFlush will condition the internal hydraulic system to help optimize both overall system
performance and fluid biodegradability.
1.
Run equipment until warm. Drain petroleum hydraulic fluid and replace all hydraulic filters.
2.
Fill system with EnviroLogic ® BioFlush. Run equipment for 5 minutes until fluid is completely circulated.
3.
Drain the BioFlush and replace hydraulic filters.
4.
Fill system with approved Greenscare™ biodegradable ISO VG 46 hydraulic oil.
The hydraulic system is now optimised for fluid biodegradability in the event of leakage.
When changing from vegetable to mineral oil there is no need to flush the system.
8.8

HYDRAULIC TEST PORT ____________________________________________

Hydraulic service test ports are provided to enable oil pressure & oil condition to be checked should any
problems with the hydraulic system are experienced
All tests, unless stated otherwise, must be carried out with the hydraulic oil at normal working temperature.
TEST PORT
A.
Charge Pressure Port - Located under operators platform on left hand chassis rail.
B.
Transmission Forwards - Located under the Exhaust bulkhead, accessible from underneath the machine.
NOTE: Any hydraulic related issues contact your Ransomes Jacobsen dealer for a full fault diagnosis.
MAINTENANCE AND LUBRICATION 8
B
A
en-87