Desired image
Current image
When adjustment of [Perpendicularity] is necessary
Slow scan direction
(Paper feed direction)
For details on adjustment of [Lead/Side Registration], refer to "Adjusting [Lead/Side Registration]"
(P.110)
For details on adjustment of [Perpendicularity], refer to "Adjusting [Perpendicularity]" (P.111)
Adjusting [Lead/Side Registration]
With [Lead/Side Registration], you can adjust front and back sides for each tray.
1.
Check the chart, and measure the amount (mm) of misalignment in the image position.
Adjustment amount (mm) = distance (mm) of the actual image position from the edge of the paper -
10
Desired image
10 mm
Current image
2.
Press the
<Menu> button.
3.
Press the
or
4.
Press the
or
110
8 Maintenance
10 mm
10 mm
button, select [Maintenance], and press the
button, select [Image Position], and press the
Side registration
misalignment
Lead registration
misalignment
A
Fast scan direction
B
Side registration
misalignment
10 mm
Lead registration
misalignment
button.
button.