The DHCP server is enabled on each SINUMERIK server by default. The SINUMERIK
system network therefore configures itself dynamically via the DHCP protocol. Additional
information is available in the "SINUMERIK manual "Operator components and networking"
(6FC5397-1AP10-5AA0) (http://www.automation.siemens.com/doconweb/)".
USB stick for commissioning
You use a button on the HMI user interface of the SINUMERIK TCU to access the USB port
on the rear of the device. For example, you read in the series startup files on the
SINUMERIK USB stick. A maximum of one USB storage device is accessed which is
recognized first.
Note
Security threat to the system
The USB may infect the server with viruses, Trojans, spam, etc.
Use a suitable virus scanner to check the data on the USB storage medium or disable the
HMI button for access via USB.
The USB port is only available if you make the following settings for the corresponding
button in the SINUMERIK menu "Commission > HMI > Logical drive":
● "Type" = "USB local"
● "Connection" = "X204"
Keyboard language with external keyboard
Damage to the machine or plant through operating error
The set system language, for example German, also determines the keyboard language of
the externally connected USB keyboard. If you then connect an English keyboard, however,
such as is the case with a SINUMERIK connection, the keys do not have the same
meaning as is printed on them.
This may result in operating errors at the machine and personal injury or damage to the
machine or plant. To connect an English keyboard, set the system language to English
under "Language" in the Start menu "Configuration > System".