Assigning device parameters
5.3 Configuration settings of the device
● If you select the "Connect USB as drive" option (RDP only), you can access a USB
Note
Security threat to the system
The USB may infect the server with viruses, Trojans, spam, etc.
Use a suitable virus scanner to check the data on the USB memory device, or deselect
the "Connect USB as drive" option.
● If the "Automatic scaling" option is selected (Sm@rtServer only), the device attempts to
If the server does not support this function, an error message will be displayed. Depending
on the height-to-width ratio, the server screen is displayed within a black bar.
5.3.5.4

Setting up startup connection

Introduction
You can designate each client-server connection as an autostart connection. This means
that this client-server connection will also be started every time the device starts. The
autostart connections can be restarted even after the configuration settings have been
changed.
Note
Limited number of client-server connections
A maximum of 5 client-server connections can be started at the same time. If a sixth
connection is activated, an error message appears.
Only one SINUMERIK connection can be started at any one time. The screen can no longer
be operated when you activate a second connection.
The order cannot be defined for startup. Therefore, which of the autostart connections will
ultimately be displayed on the screen is undefined. However, you can generally switch
between the client-server connections.
Procedure
Proceed as follows to identify a client-server connection as an autostart connection:
1. Choose "Configuration > Connections" in the Start menu.
2. Select a client-server connection.
3. Touch the "Edit" button to confirm.
4. Select the "Autostart connection" option.
56
memory device connected to the Industrial Thin Client on the touch screen. The USB
data are transferred to the server and displayed there in Windows Explorer for the
devices. For additional information, refer to the section "Operating a USB memory device
(Page 95)".
request a server screen that will be displayed as a full screen on the device.
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02