Fpx 36-Dv Blower Removal - Travis Industries Spirit 300 GS Service Manual

Table of Contents

Advertisement

FPX 36-DV Blower Removal

Warning
Make sure power is disconnected to
the heater prior to conducting service -
remove the fuse or disable the breaker
servicing the heater.
Warning
Shut off gas to the heater - you may
need to disconnect the gas line
depending upon the heater location
and the type of gas connection.
1
Remove the faceplate of the fireplace (see page 3-5).
2
Disconnect the flex tube from the gas control valve.
3
Remove the nuts holding the blower in place.
These nuts hold the
blower in place.
7/16Ó
Socket
4
Move the blower to the left of the gas control valve and thread it out of the appliance.
5
Disconnect the wires leading to the blower (orientation does not matter when re-installing).
6
When re-installing, make sure the rubber
grommet fits into the bracket. Place the
washer over the grommet and tighten the
nut just enough to slightly compress the
grommet.
Travis Industries
Blower Components
Gas T-Shoot Guide
Hold the fitting in place with the 3/4"
wrench while unscrewing the flex tube
with a 7/8Ó wrench.
Flex Tube
Fitting
These nuts hold the
blower in place.
Rubber
Grommet
Washer
Nut
Bracket
(on blower)
5 - 9
Gas Control Valve
7/16Ó
Socket
19203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spirit bayDiscoveryHeritage bay700Avanti36 ... Show all

Table of Contents