5 - 2
Avalon 700 (B-Vent & DV) Blower Removal
Warning
Make sure the power cord is disconnected prior to conducting service.
Warning
Shut off gas to the heater - you may need to disconnect the gas line
depending upon the heater location and the type of gas connection.
Note:
If the Avalon 700 was installed as an insert, remove it from the fireplace (remove the
panels, glass and logs first to prevent damage while moving the insert).
1
Remove the two screws on the cover plate
around the gas inlet. Unscrew the nine
screws holding the rear panel in place.
Cover Plate
3
Remove the nuts holding the left side panel
to the baseplate.
Remove these nuts (left side only)
5
Remove the left side panel by pushing it
backwards and sliding it down (NOTE: the
top panel has an ÒLÓ shaped notch for
attachment).
6
With the left rear of the heater exposed, the
blower assembly can be accessed. Follow
the directions on page 5-5 (A20 Blower
Assembly Removal & Disassembly) to
remove the blower from the heater.
Travis Industries
Blower Components
Gas T-Shoot Guide
2
Swing the rear panel to the left and
disconnect the molex connector leading
from the power cord.
Remove the Molex Connection
4
Loosen the nuts holding the left side
panel to the convection top (three turns).
Loosen these nuts (left side only)
19203