Thermopile Removal; Thermocouple Removal - Travis Industries Spirit 300 GS Service Manual

Table of Contents

Advertisement

Burner Pan Components
4 - 10
Thermopile
Refer to the section on pilot assembly removal (for 1997 or later models see page 4-8, 1996 or earlier
see page 4-7). Use a 7/16" open end wrench to remove the thermopile from the pilot assembly.
Disconnect the theropile from the gas control valve following the instructions below.
PILOT ADJ
Gas Control Valve
Thermocouple
Remove the burner pan (for 1997 or later models see page 4-2, 1996 or earlier see page 4-1).
Place the burner pan upside down and remove the thermocouple with a 7/16" open end wrench (see
the illustration on page 4-7 for the location of the thermocouple).
Disconnect the thermocouple wire from the gas control valve following the instructions below.
Travis Industries
Removal
Removal
Use a 3/8" open end
wrench to remove the
thermocouple wire.
Copper Tube
Gas T-Shoot Guide
Use a standard screwdriver to
Standard
remove the two thermopile wires
Screwdriver
from the gas control valve.
Red Thermopile Wire
White Thermopile Wire
PILOT ADJ
B-Vents Only
Thermocouple
Connector
19203