Removing the Center Guide Modules

The MGX 8850 (PXM1E/PXM45), MGX 8850/B and MGX 8950 switch each use a standard plenum.
Starting May 2003, with MGX Release 4, the standard plenum has the ability to support an air filter. The
purpose of the filter is to keep dust out of the interior of the switch.

Scheduled Maintenance of the Air Filter

This section describes the part numbers and procedures required for air filter maintenance.

Replacing the Filter

It is recommended that you visually inspect the air filter weekly. Replace the filter as required. The
Note
dustier the environment, the more frequently the filter should be replaced.
Note
Cisco does not provide filter replacements for the MGX 88xx switches. Replacement air filters may be
obtained from a third party.
Filters cannot be cleaned. They must be replaced.
Warning
To replace the air filter:
Ensure that the door on the MGX switch is fastened closed. The door must be closed to ensure proper
Step 1
alignment after service.
Loosen the captive screws to the right and left of the air intake plenum.
Step 2
Open the plenum, which is hinged at the bottom.
Step 3
Insert a new filter into the plenum.
Step 4
Close the air intake plenum. Tighten the captive screws.
Step 5
Step 6
Record the date each time you replace the filter.
Removing the Center Guide Modules
To install double-height cards where single-height cards were installed, remove the center guide modules
located at the front of the card cage (see
card slots, so plan front card replacements accordingly. Install a blank faceplate over each empty slot in
the new configuration to facilitate air flow and EMI containment.
Cisco MGX 8800/8900 Series Hardware Installation Guide
6-14
If the air filter inside is soiled, remove and discard the filter. Proceed to
If the air filter is clean, proceed to
Chapter 6
Maintaining the Cisco MGX Switch or Gateway
Step
5.
Figure
6-7). Each center guide module encompasses two front