Chapter 5
Installing the Cisco MGX Switch or Gateway
Note
Using a lift to install a fully loaded MGX 8850, MGX 8850/B, or MGX 8880 system in a rack greatly
simplifies the installation process, because the modules do not need to be removed from the chassis.
Before proceeding with the installation, verify that all of the ordered parts are present and in good
condition. Store a record of the parts and serial numbers. If any parts are missing or damaged, contact
your sales representative.
Proper ESD protection is required whenever you handle Cisco equipment. Installation and maintenance
Caution
personnel should be properly grounded through the use of grounding straps to eliminate the risk of ESD
damage to the equipment. Modules are subject to ESD damage whenever they are removed from
the chassis.
Table 5-1
Installation Checklist—MGX 8850, MGX 8850/B, or MGX 8880 Systems
Rack-Mounted System
Check Steps
(Without Lift)
Step 1
Install stability plate for seismic anchoring
Step 2
Ground the frame bonding ground connection for a Cisco-supplied rack
Step 3
Measure Rack Space
Step 4
Prepare for rack installation
Step 5
Install the AC Power Supply Tray, as necessary
Remove the AC power supplies from the AC power supply tray
Install the AC Power Supply Tray(s)
Reinstall the AC Power Supplies
Step 6
Install the Air Intake Plenum
Step 7
Install the Lower Fan Tray
Step 8
Install the switch without a
Mechanical Lift
Prepare for Installation
Remove the Front Cards
Remove the Back Cards
Remove the Back Cards from
an APS Assembly
Install the Switch in the Rack
Reinstall the APS Assembly
Reinstall the Back Cards
Reinstall the Front Cards
Step 9
Install the Upper Fan Tray
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Installing the MGX 8850 (PXM1E/PXM45) Switch, MGX 8850/B or MGX 8880 Media Gateway
Rack-Mounted System (with Lift)
Install the switch with a
Mechanical Lift
Install the Switch in a 19-Inch
or 23-Inch Rack
Install the Switch in a 19-Inch
Cabinet
Cisco MGX 8800/8900 Series Hardware Installation Guide
Cisco Cabinet System
Connect the Fan tray power cables
to the switch
Connect the AC power supply tray
to the switch
Connect the DC PEM to the switch
Connect the Back Cards.
Connect the Console Port.
Connect Power to the switch
Connect AC Power to the
Switch
Connect DC Power to the
Switch
Connect the External Clock
(optional)