Figure 6-13 Mgx 8850/B Rcon Installation - Cisco MGX MGX 8800 Hardware Installation Manual

Cisco systems switches installation guide
Hide thumbs Also See for Cisco MGX MGX 8800:
Table of Contents

Advertisement

Chapter 6
Maintaining the Cisco MGX Switch or Gateway
Step 4
Place the RCON assembly over the RCON mounting bar, positioning the RCON alignment flange over
the top edge of the bar and the RCON alignment pins through holes in the bar (See
If you are installing the 1:5 RCON, there is a single mounting position on the mounting bar.
If you are installing the 1:3 RCON, there are two mounting positions on the mounting bar, offset by
one slot. The 1:3 RCON in
Note
Figure 6-13
1
2
3
1
Mounting bar for RCON
2
Alignment flange on 1:5 RCON assembly
3
Mounting screw on 1:5 RCON assembly
4
Left mounting location for 1:3 RCON
Tighten the two RCON fasteners, first by hand and then using a screwdriver.
Step 5
Install additional RCONs, if desired. You can install up to four RCONs, on the left and right-hand side
Step 6
of the top and bottom bay.
Reinstall all back cards.
Step 7
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Figure 6-13
Be careful not to bend or damage the pins on nearby back card connectors.
MGX 8850/B RCON Installation
Installing or Removing Redundancy Connectors
is shown in the left-hand mounting location.
5
Alignment holes for RCON
6
Alignment flange on 1:3 RCON assembly
7
Mounting screw on 1:3 RCON assembly
Cisco MGX 8800/8900 Series Hardware Installation Guide
Figure
6-13).
4
5
6
7
6-23