Chapter 5
Installing the Cisco MGX Switch or Gateway
Figure 5-72
Position the APS assembly in the appropriate card slots.
Step 4
Note
Slide the APS assembly all the way into the slot until it is properly seated in the backplane. The
Step 5
faceplates of the back cards are flush with the card cage when the APS assembly is properly seated.
Tighten the captive screws on the back cards with the appropriate screwdriver. If you have difficulty
Step 6
inserting the captive screws, verify that the screws are aligned with the holes.
Reinstall the Back Cards
All cards must be fully seated in the chassis. When installing the back card, apply even pressure to the
Note
left and right of the faceplate to make sure that the card is fully seated.
The card should slide in and out with only slight friction on the adjacent board's EMI gaskets. Do not
force the card. Investigate any binding.
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Two Back Cards in the MGX8830-APS-CON Connector
The extractor levers must be closed (flush with the vertical edge of the back cards, as shown in
Figure 5-71
and
Figure
5-72), or the APS assembly cannot slide properly into the chassis.
Installing the MGX 8830 or MGX 8830/B Switch
Cisco MGX 8800/8900 Series Hardware Installation Guide
5-115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgx 8900 series

Table of Contents