Upgrade Fluid Control Module
(FCM) Software
NOTE: The FCM connection is temporarily disabled
during the use of the upgrade token.
1. Turn off power to the system.
2. Remove access cover then remove key token (do
not discard token).
F
. 43: Remove Access Cover
IG
3. Insert and press software token firmly into slot.
NOTE: There is no preferred orientation of token.
4. Turn on power to the system. The red indicator light
(CK) will flash until new software is completely
loaded.
CK
F
. 44: Insert Token
IG
5. After the red indicator light shuts off, turn off power
to the system.
6. Remove software token.
3A2098A
Access
Cover
TI12334A
TI12335A
Token
7. Reinstall key token, and replace access cover.

Air Filter Maintenance

To prevent filter element damage, replace air filter every
two years or when pressure drop becomes 100 kPa
(1.0 bar, 14.5 psi) or greater; which ever occurs first.
Replacement Air Filters
Part
Description
123091
5 micron air filter
123092
0.3 micron air filter
Maintenance