System Setup

Configure Errors

Set the error type (alarm, deviation, or none) that will be
issued if the pressure, flow rate, volume, or computed
target goes outside the tolerance settings of the active
style. When an alarm occurs, the system stops dispens-
ing. When a deviation occurs, the system will continue
dispensing. See Fluid Plate x, Screen 6 (Error Type)
on page 97 for more information.
NOTE: Only the low/high pressure errors will be
enabled for systems without a flow meter.
1. With the system in setup mode, navigate to Fluid
Plate x, screen 6 (Error Type).
2. Press
to access the fields to make changes.
F
. 25
IG
3. Press
to open the Low Pressure drop-down
list, and select either Alarm or Deviation for the error
type. Press
to enter the selection.
4. Press
to move to the next field. Repeat Step 4
for each field.
5. Press
to exit edit mode.
34
Setup Maintenance
Schedule/Parameters
Set the volume (or hours) limit that will trigger a mainte-
nance advisory for the fluid supply, Voltage to Pressure
(V/P) Transducer, fluid regulator, flow meter, and all four
valves.
NOTE: Hours is shown instead of Volume for fluid
plates without a flow meter.
The Volume (or Hours) column displays the current
totalizer value. If this value exceeds the set limit, the
value will turn red and a maintenance advisory is
issued. See Fluid Plate x, Screen 7 (Maintenance
Advisory Limits), page 97, for more information about
maintenance totalizers.
To set limits:
1. With the system in setup mode, navigate to the Fluid
Plate x, screen 7 (Maintenance Advisory Limits).
2. Press
to access the fields to make changes.
F
. 26
IG
3. Enter the desired limit for the air supply and press
to enter the selection.
4. Press
to move to the next field. Repeat Step 4
for each field.
5. Press
to exit edit mode.
3A2098A