Install Bulkhead Fitting (Included In The Kit) Into The Empty Hole On The Fluid Plate; Connection - Graco PCF Instructions Manual

Table of Contents

Advertisement

Install Command Cable Kit 24B694
Follow this procedure if using the command cable kit.
1. Install bulkhead fitting (included in the kit) into the
empty hole on the fluid plate. See F
page 22.
2. Connect one end of the extension cable (included in
the kit) to connection 5 on the FCM and the other
end of the cable to the bulkhead fitting.
3. Connect command cable to bulkhead fitting and
wire to automation controller per the following pinout
table.
FCM
Command
Port
Cable Wire
Pin #
Color
Function
1
White
Command voltage (0-10 Vdc)
2
Brown
No connection
3
Green
Dispense trigger (*sourcing input)
4
Yellow
No connection
5
Gray
Dispense trigger ground
6
Pink
No connection
7
Blue
Command signal ground
8
Red
No connection
NOTE: Command cable inputs are not isolated from
PCF 24 Vdc power.
*
To turn on the dispense trigger, connect pin 3 (dis-
pense trigger) to pin 5 (dispense trigger ground).
3A2098A
. 15 on