Connect Easykey To Fluid Station Control - Graco TI12552a Installation Instructions Manual

Plural component proportioner
Table of Contents

Advertisement

Fiber Optic Strain
Relief Port
Ground Screw
I/S Power
F
. 18. EasyKey Connections and AC Power Switch
IG
Connect EasyKey to Fluid
Station Control
There are two 50 ft (15.2 m) cables to route between the
EasyKey and Fluid Station Control: the Fluid Station
Power Cable and the Fiber Optic Cable.
1. Connect the appropriate Fluid Station Power Cable
end to the EasyKey connector
2. Connect the other cable end to the Fluid Station
Control connector
3. The Fiber Optic Cable is shipped from the factory
attached to the Fluid Station connector
See F
. 18.
IG
NOTE: If you need to detach the Fiber Optic Cable from
the Fluid Station, note how the cable is routed inside the
enclosure. Never cut the fiber optic cable. Cutting can
damage the cable and will defeat the color-coded cable
connections.
4. Route the opposite Fiber Optic Cable end through
the EasyKey strain relief connector
route the cable with tight bends or kinks.
NOTE: The fiber optic cable has a minimum bend radius
of 1.6 in. (40 mm).
5. Route the fiber optic cable end through the square
adhesive backed tie holder. Connect the blue and
312778G
Graco Web
Discrete I/O Cable
Interface
Connector Ports
. See F
. 18.
IG
(J10). See F
. 20.
IG
.
. Do not
Audible Alarm
Main Power
Access Port
TI12638a
black cable connectors to the matching connectors
on the EasyKey circuit board. See F
cable connectors until they bottom out (approxi-
mately ¼ in. [6 mm]), then tighten the threaded con-
nector.
J7 (F.O In-black)
F
. 19 EasyKey Circuit Board
IG
NOTICE
To avoid cracking the circuit board, do not
over-tighten or cause excessive stress on the circuit
board connector.
6. Tighten the strain relief connector
Electrical
AC Power Switch
TI12657a
. 19. Insert the
IG
J8 (F.O Out - blue)
.
31