Event and Error Codes and Troubleshooting

NOTE: Error codes are stored in the events log and are displayed on the error report screens. Gateway error
numbers are reported over the Gateway interface.
NOTE: Error codes shown as XYZ_ represent error codes XYZ1, XYZ2, XYZ3, XYZ4, where the last digit rep-
resents the number of the fluid plate to which the error applies.
System Events and Errors
Event
Gateway
Code
Error No.
Event Name
---
0
No Active Errors
EL0X
---
Power Up
EC0X
---
Setup Values
Changed
EM0X
---
Power Down
Control Center Events and Errors
Event
Gateway
Code
Error No.
Event Name
EVUX
---
USB Disabled
MMUX ---
USB Log 90%
Full
V1G0
---
DGM Unpowered The Discrete Gateway
WSG0
---
Gateway Setup
Error
EAUX
---
Download to
USB in Process
EBUX
---
Download to
USB Complete
WSU0
---
USB configura-
tion error
3A2098A
Event
Description
Event Type
System Events and Errors
No errors
---
Control box power up
Record only
Setup change notifica-
Record only
tion
Control box power
Record only
down
Event
Description
Event Type
Control Center Events and Errors
USB download
Advisory
attempted, however,
(self-clearing)
USB activity is dis-
abled.
One or more USB log is
Advisory
90% full.
Advisory
Module does not have
logic power supplied to
it.
System settings are
Advisory
incompatible with Dis-
crete Gateway Module.
Information is currently
Advisory
being downloaded to
(self-clearing)
USB
Download to the USB is
Advisory
complete
(self-clearing)
USB configuration error Advisory
Cause
---
No action necessary
---
No action necessary
A setup value was
No action necessary if
changed on the dis-
changes were desired
play
---
---
Cause
Transfers are disabled
Clears when drive is
in Advanced Setup
removed.
screen 2.
Data in the jobs or
Download the data or
events log has not
disable USB errors.
been downloaded
recently and logs are
nearly full.
24 Vdc has not been
Connect power accord-
connected to the
ing to Appendix B -
power pins.
Discrete Gateway
Module (DGM) Con-
nection Details on
page 104.
Fluid plate 1 is not
Install fluid plate 1,
installed. Or Fluid
uninstall fluid plates 3
plate 3 or fluid plate 4
and 4.
is installed.
---
No action necessary
---
No action necessary
USB configuration
Reinstall system soft-
invalid or not present
ware on display
Errors
Solution
Solution