Configure Mode Settings

Set valve commands, including the dispense mode
(pressure, bead, shot, or full open) and flow rate or pres-
sure for each valve. The bead scale is also adjustable
from this screen.
NOTE: For a description of each dispense mode,
see Dispense Control Modes, page 101.
1. With the system in setup mode, navigate to the Fluid
Plate x, screen 2 (Mode Settings).
2. Press
to access the fields to make changes.
F
. 21
IG
3. Press
and
valve that will be used to Pressure, Bead, Shot, or
Full Open. Press
4. Use the four arrow buttons to navigate to each Fixed
Command field. Enter the desired value for each
valve that will be used. Press
value.
3A2098A
to set the mode for each
to enter each selection.
to enter each
NOTE: The ability to dispense from multiple valves
simultaneously is only allowed in either of the fol-
lowing scenarios.
Each valve is set to Pressure mode and has
identical Fixed Command values.
Each valve is set to Full Open mode.
Attempting to dispense from multiple valves simul-
taneously using any other combination will cause
an Incompatible Valves Settings alarm.
5. Press
to move to the Bead Scale field. Enter a
scale value between 50% and 150%. Press
enter the value.
6. Press
to exit edit mode.
System Setup
to