Advanced Display Module (ADM)

Upgrade Software
NOTE: Back up the custom language file (if
installed) before upgrading software. See USB Data,
page 51, for more information.
1. Turn off power to the system.
2. Remove token access panel, and then remove the
key token (do not discard token).
Access Panel
F
. 37: Remove Access Panel
IG
3. Insert and press software token firmly into slot.
NOTE: There is no preferred orientation of token.
Token
F
. 38: Insert Token
IG
4. Turn on power to the system. The red indicator light
(BL) will flash until new software is completely
loaded.
5. After the red indicator light shuts off, turn off power
to the system.
6. Remove software token.
7. Reinstall key token, and replace token access
panel.
Cleaning
Use any alcohol-based household cleaner, such as
glass cleaner, to clean the display.
3A2098A
Upgrade Gateway Module
Software
NOTE: The Gateway module connection to the sys-
tem is temporarily disabled during the use of
upgrade tokens. The following instructions apply to
all Gateway modules.
1. Turn off power to the system.
2. Remove the access cover.
r_24E451_3B9900_3a
F
IG
3. Insert and press token firmly into slot.
NOTE: There is no preferred orientation of token.
BL
4. Turn on power to the system. The red indicator light
r_24E451_3B9900_4a
F
IG
5. After the red indicator light shuts off, turn off power
6. Remove token.
7. Replace access cover.
. 39: Remove Access Cover
(CK) will flash until new software is completely
loaded.
CK
Token
. 40: Insert Token
to the system.
Maintenance
Access
Cover
TI12319A
TI12320A
67