Pail Low and Empty Sensor Kit (255233)

The Pail Low and Empty Sensor Kit is used to indicate
that a pail is EMPTY or LOW, depending on the adjust-
ment of the proximity switch. The kit contains a sensor
mounting bracket (A), activator (B), sensors (C), and a
cable for connecting to the Therm-O-Flow 20 control
panel. See F
. 26.
IG
The low and empty conditions will be displayed in the
status bar of the EasyKey display. An optional light tower
is also available.
With the optional light tower a yellow light indicates a
pail low condition. A flashing yellow light indicates a pail
empty condition. In a tandem system a red light indi-
cates both pails are empty. See Light Tower Kit
(253547), page 53.
Proximity Sensor Connections
F
. 26: Optional Low Level Kit
IG
312094K
When ordering this kit individually to connect to an exist-
ing Therm-O-Flow 20 unloader assembly, use the bolts,
screws and washers provided to mount to the closest
ram post to the control box. Mount the limit switches to
the bracket as shown.
Increasing the distance between the low and empty sen-
sors (C) increases the heat up time for the tandem sec-
ondary system. Lowering the pail empty sensor forces
the heated platen lower into the pail. If this is set too low
the pump could cavitate causing a system alarm.
A
C
Accessories
B
TI10243A
TI10244A
55