Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual page 375

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

▶ Fit the slimline ODD into the slimline ODD installation frame.
▶ Ensure that the four pins on the frame (see circles) engage with the screw
holes on the drive.
▶ Ensure that the ODD is properly seated in the installation frame.
Figure 248: Mounting the slimline ODD module in the Multibay box
▶ Insert the slimline ODD module into the Multibay box (1) and push back until
the locking tab (2) engages.
Removing accessible drive dummy covers
▶ If applicable, remove the accessible drive filler cover from installation bay 1,
see
"Removing accessible drive filler covers" on page
▶ If applicable, remove the accessible drive cover from installation bay 1, see
"Removing accessible drive covers" on page
Installing the Multibay box
▶ Ensure that the four mounting brackets in installation bay 1 have not been
bent out (see
Figure
▶ Open the locking bar, see
page
89.
TX1330 M4
241).
"Opening the accessible drive locking bar" on
Upgrade and Maintenance Manual
Accessible drives
92.
95.
375