Regency E33S-NG1 Sunrise Owners & Installation Manual

Hide thumbs Also See for E33S-NG1 Sunrise:

Advertisement

E33 Sunrise
MODELS:
www.regency-fire.com
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
918-747b
FpI FIREplAcE pRODUcTS INTERNATIONAl lTD. 6988 Venture St., Delta, Bc canada, V4G 1H4
Gas Insert
E33S-NG1 Natural Gas
Installer: please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: please keep these instructions for future reference.
E33S-LP1 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
Immediately call your gas supplier
If you
Owners &
Installation Manual
do not use any phone in your
building.
from a neighbour's phone. Follow
the gas supplier's instructions.
cannot reach your gas
supplier, call the fire department.
01/17/12

Advertisement

Table of Contents
loading

Summary of Contents for Regency E33S-NG1 Sunrise

  • Page 1 Owners & Installation Manual MODELS: E33S-NG1 Natural Gas E33S-LP1 Propane www.regency-fire.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your FPI Fireplace. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 3: Table Of Contents

    Warranty ..............39 Wiring Diagrams ............17 Optional Remote Control ..........18 Optional Wall Thermostat ...........18 Optional Reflective Panel Installation ......19 Glass Crystal or Optional Ceramic stones....22 Glass Door Installation ..........22 Contemporary Faceplate &..........23 Door Frame Installation ..........23 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 4: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 6: Dimensions

    Dimensions 32-1/8” (816mm) 24-3/8” (619mm) 47-1/2” (1207mm) 1-1/8” 11-3/8” (28mm) (290mm) 13-3/4” (349mm) 27-7/8” (708mm) 2-7/8” (72mm) 16-1/2” (419mm) Regency E33S-1 Sunrise Gas Insert ®...
  • Page 7: Installation

    Due to eXcessive lint from carpeting, beDDing material, etc. it is imperative that control compartments, burners anD circulating air passagewaYs of the appliance be Kept clean. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 8: For Your Safety

    If the factory built fireplace* height is too low unless all original parts have been replaced, and the fireplace re-approved by the authority for your Insert, you may remove the smoke having jurisdiction." baffle plate and damper from the factory Regency E33S-1 Sunrise Gas Insert ®...
  • Page 9: Installation Checklist

    6) Slide the unit fully into the fireplace. from this plug. 7) Test gas pressure, refer to the "Gas Pipe Pressure Testing" section. Check aeration system, refer to "Gas Insert Aeration Systems" section. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 10: Minimum Clearances To Combustibles

    Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 11: Gas Connection

    2) Mill-pac may be used instead of high tempture silicone and screws may be used instead of gear clamps at connections of liner to inlet and vent collars. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 12: Gas Pipe Pressure Testing

    6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 13 Remove the base cover by lifting up from the back and maneover out. Remove the glass door. E33S only: Burner screws on E33S a) Remove the 2 screws at the bottom of the glass door. Base Cover Regency E33S-1 Sunrise Gas Insert ® 11/03/09 918-480d...
  • Page 14 E33S 1/4" U32S Glass Crystals Spa Stones 18) Using the allen key as shown in Fig.4, 1/2" 3/8" rotate the screw clockwise until snug, do not overtighten. Burner Orifi ce -U32S Fig.4 11/03/09 918-480d Regency E33S-1 Sunrise Gas Insert ®...
  • Page 15: Installation Of The Dc Sparker

    21) Attach the label "This unit has been converted to Propane" near or on top of the serial # decal. Ground wire from Kit 22) Replace yellow "Natural Gas" label with red "LPG" label. Ignitor Wire 11/03/09 918-480d Regency E33S-1 Sunrise Gas Insert ®...
  • Page 16 See image below as an example. Note: It should be kept away from the chain (U32S only). Chain 10) Connect the ground wire to the DC Sparker mounting bracket. 11/03/09 918-480d Regency E33S-1 Sunrise Gas Insert ®...
  • Page 17: Wiring Diagrams

    NATURAl GAS Units and Units Equipped with Dc Spark Boxes cAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 18: Optional Remote Control

    FPI offers an optional programmable remote control wires thermostat but any 250-750 millivolt rated non- 22 GA. 9 Ft. anticipator type thermostat that is CSA, ULC or to the 120V wires. UL approved may be used. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 19: Optional Reflective Panel Installation

    5) Remove the fi rebox base by lifting up from the back and maneuver out carefully. Ensure not to scratch the paint work or damage the pilot while lifting out. Firebox Base Burner Regency E33S-1 Sunrise Gas Insert ® 12/21/09 918-878...
  • Page 20 Slide the top refl ective panel in place over top of the heat defl ector. 9) Secure top panel using 2 screws at the back - then tighten the 3 screws at the front 918-878 12/21/09 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 21 12) Install the right side panel - secure in place one screw and a panel clip. 13) Re-install fi rebox base. 14) Re-install pilot assembly cover. 15) Re-install burner. 16) Re-install louvers and fl ush door. 17) Turn on power and gas supply. 12/21/09 918-878 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 22: Glass Crystal Or Optional Ceramic Stones

    Refer to Diagram 3. Secure door by fastening with two screws located at bottom of glass door, refer to Diagram 1. Diagram 2 Screws Diagram 1 Diagram 3 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 23: Contemporary Faceplate

    2) Connect the grey coated female ends of the black & red fan wires from the unit to the male ends of the fan rheostat on the left side of the faceplate as shown. Faceplate Tabs Fan Rheostat Regency E33S-1 Sunrise Gas Insert ® 11/03/09 918-750...
  • Page 24 7) Secure the hinge to the bottom fl ange of the fi rebox with 2 screws Glass Door from step 6. Repeat for other side. Door Frame Flange 10) Close the bottom louver. Completed Faceplate & Door Frame Installation Spacer Screw 918-750 11/03/09 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 25: Optional Hearth Trim

    NOTE: Don't tighten the screws down completely at this point, suit fi nishing. do a trial fi t to the unit, make any necessary adjustments and when it fi ts properly then tighten screws. Diagram 2 Diagram 1 06/17/08 918-756 Regency E33S-1 Sunrise Gas Insert ®...
  • Page 26: Low Profile Faceplate Installation

    Attach the 2 bottom louver hinges to the bottom fl ange on the Diagram 3 fi rebox using 2 screws per hinge. 3) Connect the female ends of the ON/OFF switch - to the ON/OFF switch in the control box. Regency E33S-1 Sunrise Gas Insert ® Diagram 6 Diagram 4...
  • Page 27 Take the outer faceplate, line up the openings on the left and right legs and install onto the inner faceplate panel pins. Outer faceplate Inner faceplate panel pins 46-15/32” (1180) 42-7/16” (1078mm) Diagram 9 33-5/16” (846mm) Regency E33S-1 Sunrise Gas Insert ® 09/27/11 918-887...
  • Page 28: Optional Hearth Trim Installation

    2 screws on each side. Hearth Trim Clip Diagram 6–Hearth Trim Clip 5) Reinstall backing plate. Hearth Trim Diagram 3–Hearth Trim Secured to Backing Plate 6) Reinstall outer faceplate. Regency E33S-1 Sunrise Gas Insert ® 919-094 11/30/11...
  • Page 29: Final Check

    The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 30: Copy Of Lighting Instruction Plate

    Unit Body and Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds which will be heard throughout the cycling process. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 31: Maintenance

    NOT BE plAcED ON OR NEAR 1) Check the Venting System for corrosion in THE ApplIANcE. areas that are exposed to the elements. These will appear as rust spots or Regency E33S-1 Sunrise Gas Insert Regency E33S-1 Sunrise Gas Insert ®...
  • Page 32: Valve Tray Replacement

    5) Remove the glass door. a) Remove the 2 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom and lift up and out. Burner Regency E33S-1 Sunrise Gas Insert ®...
  • Page 33 9) Disconnect the ON/OFF connector wires from the valve. NOTE: For LP units disconnect the DC Sparker ignitor wire from the valve. 12) Disconnect the inlet gas line. 13) Replace valve and reverse steps. ON/OFF Wires Regency E33S-1 Sunrise Gas Insert ®...
  • Page 34: Fan Replacement

    Remove the 2 screws shown below at the bottom of the glass door b) Swing the door out 45 from the bottom and lift up and out. Burner 8) Remove the base cover by lifting up from the back and maneover out. Base Cover Regency E33S-1 Sunrise Gas Insert ®...
  • Page 35 13) Lift up the left side of the fan and disconnect the ground wire shown. 14) Remove the fan from the unit by carefully lifting up and ensure not to damage the pilot assembly. 15) Replace fan and reverse steps. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 36: Main Assembly

    Orifice #42 - NG 904-163 Orifice #54 - LP 936-170 Orifice Gasket 79) 341-525 Burner Assy - NG/LP 82) * Base Cover 918-747 Manual * Not available as a replacement part. Regency E33S-1 Sunrise Gas Insert Regency E33S-1 Sunrise Gas Insert ® ®...
  • Page 37: Accessories

    93) * Hinges 910-246 Burner ON/OFF Switch 910-330 Fan Speed Control 120V 904-569 Fan Speed Control Knob 100) 341-907 Stainless Steel Reflective Panels 341-908 Black Enamel Reflective Panels * Not available as a replacement part. Regency E33S-1 Sunrise Gas Insert ®...
  • Page 38: Low Profile Faceplate

    FAcEplATE part # Description Backplate Assembly Bottom Louver Right mounting bracket Left mounting bracket Front Frame Regency E33S-1 Sunrise Gas Insert ®...
  • Page 39: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 40 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Sunrise are trademarks of FPI Fireplace Products International Ltd. printed in canada © Copyright 2012, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

E33s-lp1 sunrise