Possible deviation from the specified value
•
High pressure remains constant or in‐
creases only slightly (above the pres‐
sure while engine is not running),
•
Low pressure drops quickly to diagram
value or lower,
•
The required cooling capacity is not
reached.
•
High pressure is normal,
•
Low pressure corresponds to the dia‐
gram value,
•
The required cooling capacity is not
reached.
Note
If no fault is found for this complaint, clean the refrigerant circuit
⇒ "7 Removing contaminants from the refrigerant circuit",
page 52
.
Citigo 2012 ➤ , Fabia 2000 ➤ , Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fab ...
Air conditioning system with refrigerant R134a - Edition 10.2014
Possible cause of fault
Too little refrigerant in the cir‐
cuit or expansion valve defec‐
tive.
9. Check the pressure in the refrigerant circuit (with the A/C service station)
Rectifying fault
– Drain the refrigerant from
the refrigerant circuit.
•
The volume of refrigerant
suctioned out corresponds
approximately to the speci‐
fied filling capacity:
– Replace expansion valve.
– Newly filling the refrigerant
circuit.
– Repeat check.
•
The volume of refrigerant
suctioned out is considera‐
bly less than the specified
filling capacity:
– Search for leaks with the
leak detector, eliminate.
– Newly filling the refrigerant
circuit.
– Repeat check.