– Carfeully release cable from the clips -4-.
– Unplug connector -2- from the control motor.
– Release screws -3- and -5-.
– Pull holder -1- with control motor as far forward as possible,
until the gear segments no longer engage.
– Push outside catches at the top of the holder -1- downwards
-arrows- and remove holder with control motor.
– Remove control motor from the holder.
To this end press the catch pegs -arrows- outwards while
pushing the control motor out of the catches.
Install
Note
The spare part control motor of fresh air flap and re-circulating
air flap - V154- is on position "re-circulating air operation".
If necessary connect the control motor to the wiring loom and
switch to position "re-circulating air operation".
Control motor for heating and air conditioning unit: Note the
different versions ⇒ Electronic Catalogue of Original Parts .
– Press the control motor of the fresh air flap and recirculating
air flap into the bracket.
– Press holder with control motor in top part into the housing and
lock into position.
The gear wheels must not yet engage.