♦ Close fresh-air flap and hold shut.
♦ Insert the control motor in the housing in such a way that the
1st tooth -A- of gear wheel -2- of the control motor engages in
the opening between the 1st and 2nd tooth of gear segment
-1- of the fresh-air flap.
♦ Position the re-circulating air flap in such a way that the mark‐
ings -arrows- on the gear wheel -2- and the gear segment
-3- of the re-circulating air flap engage.
♦ Press the control motor fully into the housing.
– Screw the holder of the control motor (1 Nm).
– Insert plug connection at control motor, switch on ignition and
check operation of the control motor by pressing the re-circu‐
lating air button.
WARNING
When testing the control motor do not interfere with the gear
wheel or flap kinematics.
Note
It must be possible to smoothly adjust the fresh air flap and the
re-circulating air flap up to the stop.
If the kinematics are stiff, immediately disconnect the ignition,
remove the control motor with holder and repeat the installa‐
tion.
If the control motor was replaced, perform a basic setting
⇒ Vehicle diagnostic tester.
If the flap adjustment is smooth, proceed with the installation in
reverse sequence to the removal.
4.3

Removing and installing dust pollen filter

Removing
Note
It is possible to remove and install the filter without taking off
any damping trim panel.
A combination filter also exists. It contains an integrated odour
filter see ⇒ Electronic Catalogue of Original Parts . The re‐
moval and installation procedure is similar.
The filter insert and frame together constitute a replacement
part.
Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fabia II 2011 ➤
Heating, Air conditioning - Edition 06.2013
4. Components on the heater unit