– Lock holder for control motors with catch pegs -2- and -3-.
– Mount plug -1- and -4-.
– Inspect control motors for proper operation. Connect battery
voltage to contacts -5- and -6- of plug -1- and -4-with adapter
cables from measuring tool set V.A.G - 1594 A, B oder C- and
check control motor running. The running direction is altered
when changing the cable from positive to negative. Check all
control motors individually.
Note
If the lever and the gear wheel are not aligned, the control
♦
motor is blocked or the heating and air conditioning unit is loud
during operation and the flaps do not close properly.
If one of the control motors was replaced, perform a basic set‐
♦
ting ⇒ Vehicle diagnostic tester.
Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fabia II 2011 ➤
Heating, Air conditioning - Edition 06.2013
11. Climatronic - Air conditioner with automatic regulation)
101