Skoda Citigo 2012 Workshop Manual page 80

Hide thumbs Also See for Citigo 2012:
Table of Contents

Advertisement

Citigo 2012 ➤ , Fabia 2000 ➤ , Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fab ...
Air conditioning system with refrigerant R134a - Edition 10.2014
Possible deviation from the specified value
High pressure increases only slightly
above the pressure while engine is not
running,
Low pressure drops only slightly,
The required cooling capacity is not
reached.
Possible deviation from the specified value
High pressure increases above the
specified value,
Low pressure drops quickly to diagram
value or lower,
The required cooling capacity is not
reached.
High pressure and low pressure is nor‐
mal at first, after a certain period of time:
– the high pressure increases above the
specified value,
– the low pressure drops to diagram value
or lower,
– the required cooling capacity is no lon‐
ger reached.
High pressure and low pressure is nor‐
mal at first.
After a longer operating time, the low
pressure drops remarkably low (evapo‐
rator ices up).
76
Rep. gr.00 - Technical data
Possible cause of fault
AC compressor defective.
Possible cause of fault
Constriction or blockage in the
refrigerant circuit.
Humidity in the refrigerant cir‐
cuit.
Rectifying fault
– Clean the refrigerant circuit.
⇒ "7 Removing contami‐
nants from the refrigerant
circuit", page 52
– Replace AC compressor.
Rectifying fault
– Feel the temperature gradi‐
ent of the refrigerant circuit
with the hand.
A temperature gradient is
noticed on a component:
– In case a hose line or a pipe
is bent or constricted, re‐
place this component.
– In case of a blockage, clean
the refrigerant circuit
⇒ "7 Removing contami‐
nants from the refrigerant
circuit", page 52
.
If no fault is found:
– Clean the refrigerant circuit
⇒ "7 Removing contami‐
nants from the refrigerant
circuit", page 52
.
– Check catch pan (with des‐
sicator) and throttle and re‐
place if necessary, then
evacuate the refrigerant cir‐
cuit for at least 3 hours (see
notes).
– Clean the refrigerant circuit
⇒ "7 Removing contami‐
nants from the refrigerant
circuit", page 52
.