Skoda Citigo 2012 Workshop Manual page 27

Hide thumbs Also See for Citigo 2012:
Table of Contents

Advertisement

2.2.1
Extractor, filler and measurement con‐
nections with Schrader valve
Note
Carefully screw in the handwheel of the service coupling after
connecting the A/C service station and only so far until the
valve of the service connection is safely opened (observe the
pressure gauge, do not over-press the valve).
Carefully tighten the valve core -2- because of the low tight‐
ening torque.
These valves are available in different versions and thus have
different tightening torques; if the valve core -2- has a thread
of VG5 (5.2 x 0.7 mm, tyre valve) the tightening torque is 0.4
±0.1 Nm, a valve core with a thread of M6 x 0.75 mm has a
tightening torque of 0.9±0.1 Nm and a valve core with a thread
of M8 x 1.0 mm has a tightening torque of 2.0±0.2 Nm.
Observe the correct version of the valve core -2- and the cor‐
rect assignment of the screw cap -4- see ⇒ Electronic Cata‐
logue of Original Parts .
High-pressure side
1 - Service coupling in the refrigerant line
2 - Extractor, filler and measurement valve
3 - Sealing ring
4 - Cap
Low-pressure side
1 - Service coupling in the refrigerant line
2 - Extractor and measurement valve
3 - Sealing ring
4 - Cap
2.2.2
Extractor, filler and measurement con‐
nections with acting head valve
Note
Carefully screw in the handwheel of the service coupling after
connecting the A/C service station and only so far until the
valve of the service connection is safely opened (observe the
pressure gauge, do not over-press the valve).
The tightening torque of the valve -3- is 9±1 Nm.
Citigo 2012 ➤ , Fabia 2000 ➤ , Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fab ...
Air conditioning system with refrigerant R134a - Edition 10.2014
2. General instructions for refrigerant circuit
23