Flushing Device For The Refrigerant Circuits 6337/1 Or Follow-Up Models (Manufacturer Behr); Flushing Device For The Refrigerant Circuits 6337/1 Or Fol- Low-Up Models (Manufacturer Behr); Flushing Device For The Refrigerant Circuits 6336/1 Or Follow-Up Models (Manufacturer Waeco); Flushing Device For The Refrigerant Circuits 6336/1 Or Fol- Low-Up Models (Manufacturer Waeco) - Skoda Citigo 2012 Workshop Manual

Hide thumbs Also See for Citigo 2012:
Table of Contents

Advertisement

Citigo 2012 ➤ , Fabia 2000 ➤ , Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fab ...
Air conditioning system with refrigerant R134a - Edition 10.2014
11.3
Flushing device for the refrigerant cir‐
cuits - 6337/1- or follow-up models
(manufacturer Behr)
Note
With filter -1- and two cylindrical inspection glasses.
Depending on the type and intensity of the contamination of
the flushed refrigerant circuits, the filter in the flushing device
for refrigerant circuits must be replaced no later than after 2
flushing cycles. If a very dirty refrigerant circuit is flushed out
(the refrigerant oil from the refrigerant circuit is black and vis‐
cous or there is a lot of swarf in the refrigerant circuit), the filter
is replaced after flushing the refrigerant circuit.
11.4
Flushing device for the refrigerant cir‐
cuits - 6336/1- or follow-up models
(manufacturer Waeco)
Note
With filter -1- and one inspection glass.
Depending on the type and intensity of the contamination of
the flushed refrigerant circuits, the filter in the flushing device
for refrigerant circuits must be replaced no later than after 2
flushing cycles. If a very dirty refrigerant circuit is flushed out
(the refrigerant oil from the refrigerant circuit is black and vis‐
cous or there is a lot of swarf in the refrigerant circuit), the filter
is replaced after flushing the refrigerant circuit.
11.5
Leak detector - V.A.G 1796-
Note
The work sequence for the leak detection must be carried out
according to the relevant operating instructions enclosed with the
device.
11.6
Leak detection system - VAS 6196-
Note
The work sequence for the leak detection must be carried out
according to the relevant operating instructions enclosed with the
device.
98
Rep. gr.00 - Technical data