Caution1:
The stack tray is likely to interfere when the
mounting screws are removed from the
body frame. To avoid interference, turn the
clock plate of the stack tray shift motor
clockwise so that the tray will move down
to allow removal of the mounting screws as
shown in Figure 3-306a.
Caution 2:
When mounting the processing tray, check
to make sure that the four stacking wall rails
[15] are fitted in the processing tray unit
[14] as shown in Figure 3-306b.
COPYRIGHT © 1999 CANON INC.
CANON FINISHER-E1 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 3 MECHANICAL SYSTEM
Clock plate
Figure 3-306a
[14]
[15]
Fitted.
Figure 3-306b
3-9