Siemens SIRIUS 3RW55 Equipment Manual page 230

Soft starters and solid-state switching devices
Hide thumbs Also See for SIRIUS 3RW55:
Table of Contents

Advertisement

Functions
8.20 Monitoring
Procedure for displaying line charts
The following measured values can be shown in the line chart:
• Phase current L1 (%) and (rms)
• Phase current L2 (%) and (rms)
• Phase current L3 (%) and (rms)
• Phase current average (%) and (rms)
• Line-to-line voltages U L1-L2 [V]
• Line-to-line voltages U L2-L3 [V]
• Line-to-line voltages U L3-L1 [V]
• Active power
Operation display
1. Select the measured value to be displayed in the operation display and press the right
navigation key of the 3RW5 HMI High Feature.
The selected measured value is shown graphically in a line chart.
2. Use the left and right navigation keys of the 3RW5 HMI High Feature to switch the view
between measured values (only possible within current or voltage measured values).
3. Press the ESC key to exit the line chart view.
"Monitoring" menu
1. Select the menu item "Monitoring > Measured values".
2. Select the measured value to be displayed and press the right navigation key of the 3RW5 HMI
High Feature.
The selected measured value is shown graphically in a line chart.
3. Use the left and right navigation keys of the 3RW5 HMI High Feature to switch the view
between measured values (only possible within current or voltage measured values).
4. Press the ESC key to exit the line chart view.
The sample chart shows the actual phase current I L1 as a percentage. The scaling of the y-axis
is 200%.
230
SIRIUS 3RW55 and 3RW55 Failsafe Soft Starters
Equipment Manual, 02/2022, A5E35630887002A/RS-AF/006