Siemens SIRIUS Soft Starter 3RW5 Getting Started

Industrial controls

Advertisement

Quick Links

SIRIUS Soft Starter 3RW5 PCS 7 Library
Industrial Controls
SIRIUS Soft Starter 3RW5
SIRIUS Soft Starter 3RW5 PCS 7
Library
Getting Started
02/2020
A5E48411356002A/RS-AA/001
Security information
Preface
Product specific security
information
Introduction
Getting Started
Reference
List of Abbreviations
1
2
3
4
5
6
7

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIRIUS Soft Starter 3RW5

  • Page 1 SIRIUS Soft Starter 3RW5 PCS 7 Library Security information Preface Product specific security Industrial Controls information Introduction SIRIUS Soft Starter 3RW5 SIRIUS Soft Starter 3RW5 PCS 7 Getting Started Library Reference Getting Started List of Abbreviations 02/2020 A5E48411356002A/RS-AA/001...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Versions and Documentation ....................15 Installation ..........................15 HW Config ..........................16 CFC ............................17 Operator Station ........................22 Reference ............................. 33 List of Abbreviations ..........................35 Abbreviations .......................... 35 SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 4 Table of contents SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 5: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
  • Page 6 Security information SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 7: Preface

    Soft Starter 3RW5 PCS 7 Library - Information, versions and documentation Please find an overview of all versions, manuals, readmes, readme_oss, sample project and additional information on the internet (https://support.industry.siemens.com/cs/document/109770336). SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 8 Hardware - Automation station 1: Configuration direct on the master system Order number Description 6ES7 410-5HX08-0AB0 SIMATIC S7-400, CPU 410-5H with 1*DP and 2*PN interfaces 6ES7 407-0KA02-0AA0 SIMATIC S7-400, power supply PS 407 10A, AC 120/230V/10A standard PS SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 9 Communication module Soft Starters. PROFINET 3RW5 980-0CS00 PROFINET Standard communication module for Communication module 3RW5 Soft Starters, 1 port. 3RW5 980-0HF00 SIRIUS HMI High Feature for 3RW5 Soft Starters. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 10 Preface SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 11: Product Specific Security Information

    SIMATIC PCS 7 to support a secure operation, such as: ● User rights ● Password protection of – WinCC For more information, click here (https://support.industry.siemens.com/cs/document/60119725). SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 12 Product specific security information SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 13: Introduction

    Started" for further details and to find the manuals for your SIMATIC PCS 7 Version in the manual collection. System ● Installed and compatible SIMATIC PCS 7 version ● Installed Soft Starter 3RW5 PCS7 Library V9.0 SP2 ● SIMATIC PCS 7 Multiproject (created by Project-Wizard). SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 14 Introduction 4.1 Introduction Communication Active communication network between Engineering Station (ES) / Operator Station (OS) and the PLC. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 15: Getting Started

    Installation program will ask you to decide, which product you want to install. Below is the decision matrix: Single Station Distributed System Engineering Station Operator Station "X" - required; "-" - not required SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 16: Hw Config

    Note it down or insert it in symbol table for later usage. Each address in the symbol table should have a valid symbolic name. Note • GSD use: SI0281CF.gs? V3.0, 3RW55 device on PROFIBUS network • GSDML use: GSDML V2.34- Siemens-3RW5-20191030.zip, 3RW52 device on PROFINET network SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 17: Cfc

    If the Soft Starter template was placed in the Master data library, you will find it in the project library folder (Notation: ‘Project Name’+’_Lib’ e.g.: GS_SoSt_Lib). Expand the Master data library node ("ProjName" + "_Lib" e.g.: GS_SoSt_Lib). You will find two nodes: - Blocks - Templates SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 18 Else, select tab Libraries, located underneath the Catalog view. You will find the Soft Starter templates in the Soft Starter 3RW5 PCS 7 Library (e.g.: 3RW5_PCS7_LibV90SP2). Expand the 3RW5_PCS7_LibV90SP2 node. Now you will see two templates, 3RW52_Soft_Starter and 3RW55_Soft_Starter. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 19 (Input address of 3RW52 / 3RW55 Soft Starter device)". PZDIn03 There are two ways: • Via the already created symbolic name • Via direct input of the calculated address SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 20 4. After compilation has finished, Logs dialog will be displayed. Confirm this dialog by the Close button. 5. Updated interconnection can now be checked in the chart view by pressing F5 SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 21 These blocks can be deleted (right mouse key → delete or select block → Del). After renewed compiling and downloading to the PLC, these functionalities are no longer available for the user program. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 22: Operator Station

    If you need 3RW5Oprn block icon, you can activate it using the following steps: 1. Open CFC-Editor. 2. Open any one template example: 3RW55_Soft_Starter 3. Select the 3RW5Oprn block. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 23 5.5 Operator Station 4. Right click and select Object Properties in the context menu. 5. Check in the checkbox for Create block icon. 6. Confirm the Properties dialog by clicking OK. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 24 2 block icons as displayed. The block icons give a general feedback of the current device status to the user. Please open a faceplate for detailed information about the device. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 25 Getting Started 5.5 Operator Station Faceplates Default faceplates: 3RW5Ctrl (for 3RW55 Soft Starter) MotL (for 3RW52 Soft Starter) SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 26 Getting Started 5.5 Operator Station 3RW5Oprn 3RW5Meas 3RW5Stat SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 27 Faceplates can be pinned or closed. Further information on how to use the faceplates can be found in the online help or in the user manual provided for this library. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 28 1. Open the Standard view of MotL block. 2. Click on the button Operation. 3. 3RW52Oprn faceplate opens. Click on the Measurement button to open the 3RW52Meas faceplate. 4. 3RW52Meas faceplate opens. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 29 3. 3RW52Oprn faceplate opens. Click on the Statistic button to open the 3RW52Stat faceplate. 4. 3RW52Stat faceplate opens. Note Use the navigation button at 3RW52Meas or 3RW52Stat faceplate to return to the corresponding 3RW52Oprn faceplate. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 30 Navigation between faceplates - 3RW55 3RW55Oprn 1. Open the Standard view of 3RW55Ctrl block for 3RW55. 2. Click on the Operation button to open the 3RW55Oprn faceplate 3. 3RW55Oprn faceplate opens. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 31 5.5 Operator Station 3RW55Meas 1. Open the Standard view of 3RW55Ctrl block for 3RW55. 2. Click on the Measurement button to open the 3RW55Meas faceplate. 3. 3RW55Meas faceplate opens. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 32 2. Click on the Statistic button to open the 3RW55Stat faceplate. 3. 3RW55Stat faceplate opens. Note Use the navigation button at 3RW55Meas or 3RW55Stat faceplate to return to the corresponding 3RW55Oprtn faceplate. SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 33: Reference

    ● SIMATIC Process Control System PCS 7 CFC for SIMATIC S7 (https://support.industry.siemens.com/cs/document/109765729). ● SIMATIC Process Control System PCS 7 Engineering System (https://support.industry.siemens.com/cs/document/109754984). ● SIMATIC Process Control System PCS 7 Operator Station (https://support.industry.siemens.com/cs/document/109754982). SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 34 Reference SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 35: List Of Abbreviations

    Continuous Function Chart Engineering station Generic Station Description Human machine interface HW Config "Hardware configuration" module in the SIMATIC Manager Operator station PCS 7 Process Control System 7 Central Processing Unit SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...
  • Page 36 List of Abbreviations 7.1 Abbreviations SIRIUS Soft Starter 3RW5 PCS 7 Library Getting Started, 02/2020, A5E48411356002A/RS-AA/001...

This manual is also suitable for:

Sirius soft starter 3rw5 pcs 7 library

Table of Contents