Honda CRF450R 2009 Service Manual page 194

Hide thumbs Also See for CRF450R 2009:
Table of Contents

Advertisement

FUEL SYSTEM (PGM-FI)
Align
Loosen
the air cleaner connecting hose boot band
screw.
Remove the air
cleaner
housing
by
disconnecting
the
connecting boot from
the throttle
body.
Check that the connecting boot is sealed
properly
at the
air cleaner
housing
.
Check
the
air cleaner housing
for
damage.
Install the
removed
parts in the reverse order of
removal.
Tighten the
air cleaner connecting
boot band
screw
to
the specified width
as
shown
.
OISASSEMBL Y/ASSEMBL Y
Remove
the air cleaner housing (page
6-61).
AIR CLEANER
HOUSING
CONNECTING BOOT
6·62
/
\
1.5 N'm
(0.2
kgf'
m
,
1.1 rbf-ft
)
0.7
N'
m
(0.1
kgf-m.
a .Slb"'t)
BAND SCREW
AIR CLEANER
HOUSING
7.5
±
1.5
mm
(0.30 ± 0.06 in)
O-RING
:11
'1
AIR CLEANER
ELEMENT
RETAINING
BOLT
IAT SENSOR
ELEMENT
HOLDER

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents