Parameter ID
Deceleration time (Unit: ms)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the deceleration time for a stop by "Command ID = 9:
Explanation
Forced Stop."
Forced Stop (Command ID = 9)
Related
Command
/Parameter
Parameter ID
Out-position (Unit: pulse)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
An error is output if a difference from the target value exceeds the setting of this
Explanation
parameter becoming static.
Setting 0 is invalid.
Bit 13 "Current Saturation" becomes 1 in error read (Command ID = 15).
Related
Command
/Parameter
Parameter ID
Feed-forward gain (Unit: none)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the feed-forward gain. This is usually set at shipping.
Explanation
Setting 0 disables feed-forward.
Related
Command
/Parameter
Parameter ID
Overshoot Control (Unit: none)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set pole rearrangement. This is usually set at shipping.
Explanation
Setting 100 disables pole rearrangement.
Related
Command
/Parameter
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
Parameter
34
Name
Parameter
36
Name
Parameter
40
Name
Parameter
42
Name
Deceleration Time
Out-position width
Feed-forward Gain
Overshoot Control
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp-1sm30Sm100Kp-sm100

Table of Contents