Parameter ID
Cutoff frequency of the digital low-pass filter (Unit: Hz)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the cutoff frequency of the digital low-pass filter.
Explanation
Related
Command
/Parameter
Parameter ID
Central frequency of the first analog notch filter (Unit: Hz)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the central frequency of the first analog notch filter.
Explanation
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID
Central frequency of the second analog notch filter (Unit: Hz)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the central frequency of the second analog notch filter.
Explanation
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID
Central frequency of the third analog notch filter (Unit: Hz)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the central frequency of the third analog notch filter.
Explanation
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
Parameter
22
Name
Parameter
23
Name
Parameter
24
Name
Parameter
25
Name
Digital
Low-pass
Frequency
First Analog Notch Filter Central
Frequency
Second Analog Notch Filter Central
Frequency
Third Analog Notch Filter Central
Frequency
Filter
Cutoff
73