Canon GALVANO GC-251 User Manual page 54

Digital galvano scanner system
Table of Contents

Advertisement

Command ID
-
Data
0: Command execution successful
Return
1: Command execution unsuccessful
Value
This command is used for a stop before the target position during movement by
Explanation
Command ID = 8.
Command ID = 8 Data = 0: Movement Start
Related
Command
Command ID
0: Absolute position
Data
1: Relative position
0: Command execution successful
Return
1: Command execution unsuccessful
Value
This command is used to specify a position coordinate system for setting by "Command
ID = 20: Target Position Setting."
Before setting a target position, this command should be executed.
Absolute position: Position with the origin as 0
Explanation
Relative position: Distance from the current position
This command should be executed each time a target position is set because its setting
is not retained after the start of movement.
Step movement procedure
Related
Command
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
9
10
Command ID = 10: Target Value Setting Mode
Command ID = 20: Target Position Setting
Command ID = 8 Data = 0: Movement Start
Command
Forced Stop
Name
Command
Target Value Setting Mode
Name
54