Canon GALVANO GC-251 User Manual page 71

Digital galvano scanner system
Table of Contents

Advertisement

Parameter ID
High-speed Serial Communication Offset (Unit: pulse)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
Set this parameter, when a center position of the high-speed serial communications
Explanation
data is offset.
This is effective, when operating by high-speed serial communications.
0 is set usually.
E.g. Data = 100
Related
Command
/Parameter
Parameter ID
Central frequency of the first digital notch filter (Unit: Hz)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the central frequency of the first digital notch filter.
Explanation
First Digital Notch Filter Q Value (Parameter ID = 17)
Related
First Digital Notch Filter Depth (Parameter ID = 18)
Command
/Parameter
Parameter ID
Q value of the first digital notch filter (Unit: ×100)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the Q value of the first digital notch filter.
Explanation
Set a value multiplied by 100.
First Digital Notch Filter Central Frequency (Parameter ID = 16)
Related
First Digital Notch Filter Depth (Parameter ID = 18)
Command
/Parameter
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
15
High-speed serial communication data(16bit) 0x8000 = 100 encoder pulse position.
16
17
High-speed Serial Communication
Parameter
Offset
Name
First Digital Notch Filter Central
Parameter
Frequency
Name
Parameter
First Digital Notch Filter Q Value
Name
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp-1sm30Sm100Kp-sm100

Table of Contents