Parameter ID
Raster scan start position (Unit: 0 or 1)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the start of raster scan (operation by command) from the
Explanation
negative or positive side.
Raster Scan Time (Parameter ID = 26)
Related
Raster Scan Duty Ratio (Parameter ID = 27)
Command
Raster Scan Angle (Parameter ID = 28)
/Parameter
Raster Scan Interval Time (Parameter ID = 30)
Parameter ID
Z-phase (0-point position) offset value (Unit: pulse)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set an offset from the actual Z-phase position for determining
Explanation
the 0-pulse position.
Related
Command
/Parameter
Parameter ID
Acceleration time (Unit: ms)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is valid when "Command ID = 18: Acceleration Control" is ON.
Explanation
Set the time until the velocity reaches the value set by "Parameter ID = 2: Max Velocity"
in step movement (movement by command).
If 0 is set, the target command of the maximum velocity is followed from the start of
movement.
Acceleration control (Command ID = 18)
Related
Maximum velocity (Parameter ID = 2)
Command
Movement start (Command ID = 8)
/Parameter
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
31
0: Scan start from the negative side
1: Scan start from the positive side
32
33
Parameter
Raster Scan Start Position
Name
Parameter
Z-phase Offset
Name
Parameter
Acceleration Time
Name