For the ROM Write of the parameter, a reply with data has been sent by all means by a controller.
The content of data is different by a parameter. (For details, see 7-3, "Parameter Details.")
(Note) Please make the ROM write of the parameter after enough confirmation. Depending on
value for change, the controller may not start normally.
Parameter ROM Write send
E
Axis No.
Axis No.
1 or 2
E.g. LQ gain parameter ID = 6
E1P006 / 4500 (LF)
(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a)
Parameter ROM Write reply
E
Axis No.
Axis No.
1 or 2
E.g. LQ gain parameter ID = 6
E1P006 / 4500 (LF)
(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a)
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
P
Parameter
Command ID
Decimal, 3-digit
(See 7-1 for details)
E
1
P
Parameter
Command ID
Decimal, 3-digit
(See 7-1 for details)
E
1
Command ID
Data = 4500
P
0
0
6
Command ID
Data = 4500
P
0
0
6
/
Data
Parameter setting
Decimal
/
4
5
0
/
Data
Parameter
successful / unsuccessful
0 or 1
/
0
(LF)
Delimiter
Delimiter
LF or CR
0
(LF)
Delimiter
setting
Delimiter
LF or CR