2.7.1
RS-232C command input
RS-232C command input allows the following:
•
Operation setting
•
Parameter setting
•
Error processing
•
Status check
(For details, see 7, "Commands.")
If position data send by high-speed serial communication is disabled, RS-232C command input is
enough for the following:
•
Step movement
•
Raster scan (Continuous oscillation of a certain angle at a fixed frequency)
(Communication specifications)
Wiring
Communication rate
Data length
Stop bit
Parity
Data format
Delimiter code
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
Cross wiring
38400 bps
8 bits
1
None
ASCII code
LF (0x0a) or CR (0x0d)