Command ID
0: Raster scan stop or Internal Clock mode
3: Raster scan start
7: High-speed serial communication mode
Data
8: Raster scan start by the external trigger signal input (one way scan)
9: Raster scan start by the external trigger signal input (Coming and going scan)
0: Command execution successful
Return
1: Command execution unsuccessful
Value
0: Raster scan stop or Internal clock mode
3: Raster scan start (Continuous scan)
7: High-speed serial communication mode
Explanation
8: Raster scan start by the external trigger signal input (one way scan)
9: Raster scan start by the external trigger signal input (Coming and going scan)
Raster scan movement procedure
Related
Command
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
23
If this command is sent during a raster scan, the scanner stops after moving to the
scan start position.
This command is also used for a return from high-speed serial communication
mode to internal clock mode. In the case of two axis control, it is necessary to
execute this command for each axis.
Raster scan starts after step movement to the scan initial position.
This command switches the mode to high-speed serial communication from
internal clock mode. However, high-speed serial communication signals should be
input in advance. In the case of two axis control, it is necessary to execute this
command for each axis.
(For details, see 6.2, " Operation that synchronizes with external trigger Signal
input")
(For details, see 6.2, "Operation that synchronizes with external trigger Signal
input")
Parameter ID = 26: Raster Scan Time
Parameter ID = 27: Raster Scan Duty Ratio
Parameter ID = 28: Raster Scan Angle
Command ID = 8: Data = 6: Step Movement of the raster scan initial position
Command ID = 23: Data = 3: Raster Scan Start
Command ID = 23: Data = 0: Raster Scan Stop