Parameter ID
Scan Time (Unit: See Explanation.)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This command is used to set the raster scan time (operation by command).
Explanation
The scan time is the set value × 10 μs.
E.g. For the interval of 100 ms, set 10000 (10000 × 10 μs = 100 ms).
Raster Scan Duty Ratio (Parameter ID = 27)
Related
Raster Scan Angle (Parameter ID = 28)
Command
Raster Scan Interval Time (Parameter ID = 30)
/Parameter
Raster Scan Start Position (Parameter ID = 31)
Parameter ID
Raster scan duty ratio (Unit: %)
Data
0: Parameter setting successful
Return Value
1: Parameter setting unsuccessful
This parameter is used to set the duty ratio of raster scan (operation by command).
Explanation
(See Explanation of Parameter ID = 26.)
Raster Scan Time (Parameter ID = 26)
Related
Raster Scan Angle (Parameter ID = 28)
Command
Raster Scan Interval Time (Parameter ID = 30)
/Parameter
Raster Scan Start Position (Parameter ID = 31)
CANON Digital Galvano Scanner System KP-1SM Series + GC-251
Users Manual 1.00
26
CW
CW
Scan Angle 
Scan Angle 
(+)
(+)
0
0
Scan Angle 
Scan Angle 
(−)
(−)
CCW
CCW
27
Parameter
Name
Raster Scan Time
Raster Scan Time
Parameter
Name
Raster Scan Time
Raster Scan Duty Ratio
74