Adjustment Conditions (1)

Initial:
Immediately after the power is turned on, if one of the following
conditions are met.
» Time after drum motor stops (SP3522-002)
» Temperature change since the previous line position adjustment
» Number of prints (SP2193-016) since the previous line position
When the machine recovers from the energy saver mode, if one
of the following conditions are met.
» Time after drum motor stops or main power on (SP3522-002)
» Temperature change since the previous line position adjustment
» Number of prints (SP2193-016) since the previous line position
Done either once or twice (or not done), depending on
temperature change since the previous line position adjustment.
The machine checks the above conditions at power
on/recovery. Then, line position adjustment is done if one of the
conditions occurs.
Slide 128
No additional notes
(SP2193-008/011)
adjustment
(SP2193-008/011)
adjustment
128